REMOVAL AND REPLACEMENT OF AGITATORS

IntelliCarb Training Manual

REMOVAL AND REPLACEMENT OF AGITATORS

To Remove Agitators For Cleaning (300 shown)

NOTE: All other models have only one agitation Assembly.

LEFT HAND

RIGHT HAND AGITATOR

WITH HOLE IN UPRIGHT

AGITATOR

 

 

O–RING

COUNTERCLOCKWISE

CLOCKWISE

ROTATION

ROTATION

FRONT (VALVE SIDE) VIEW FROM TOP OF DISPENSER

FIGURE 14

1.Lift agitator and disc from unit.

2.Remove O-Ring starting at notch. Warm the O-Ring with water to ease removal.

3.Lift the plastic agitator disc off of the stainless-steel agitator.

4.Replace by reversing steps.

NOTE: Refer to Sanitize Procedure in the Owners Instruction for complete cleaning and sanitiz- ing instructions.