InelliCarb Training Manual
INSTALLATION
1.Locate the dispenser indoors on a level counter top.
A.LEG OPTION
Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit. The installer must provide flexibility in the product and utility supply to permit shifting the position of the dispenser sufficiently to clean the area beneath it.
B.COUNTER MOUNTING
If counter mounted the ice drink dispenser must be sealed to the counter. The template drawing indicates where openings can be cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on the counter using the template drawings. Cut openings in counter.
Apply a continuous bead of NSF International (NSF) silastic sealant (Dow 732 or equal) approxi- mately
2.The beverage tubes, drain tube and power cord are routed through the large opening in the bottom of the unit. See the mounting template for locating the required clearance opening in the counter for these utility lines.
3.Drip tray assembly: Route the drain tube to an open drain with the end of the tube above the “flood” level of the drain. Use the tubing, fittings, clamps, and insulation provided with the Dispenser to assemble the drain. The completed drain line must pitch continuously downward and contain no “traps” or improper drainage will result. Must have a 4 inch air gap between drain line and drain.
NOTE: This equipment must be installed with adequate backflow protection to comply with fed- eral, state, and local codes.
NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in the plain water inlet supply line. A Cornelius Water Filter (P/N 313860000) and QUICK DISCON- NECT SET (P/N 313867000) are recommended.
CAUTION: Check the minimum flow rate and the maximum pressure of the plain water inlet supply line. MINUMUM FLOW RATE MUST BE AT LEAST
4.Locate the carbonator pump assembly and connect probe wires from Ice/Drink Unit and pump. Con- nect inlet water to pump and pump outlet to Ice/Drink Unit using
NOTE: Locate carbonator assembly within 6 feet of the dispenser. Do not lengthen the control board harness.
5.Connect the beverage system product tubes as indicated in applicable Plumbing Flow Diagram, see page 19. This work should be done by a qualified service person.
NOTE: Water pressure for non carbonated beverages must be 60 P.S.I. minimum.
NOTE: See applicable Flow Diagram or Decal on the lower front of the unit for the location of syrup and water connections.
6.Clean the hopper interior.
7.Connect the two power cords to a 120 volt, 60 cycle,