Ultra37000 CPLD Family

5.0V Device Characteristics

Maximum Ratings

(Above which the useful life may be impaired. For user guide- lines, not tested.)

Storage Temperature

–65°C to +150°C

Ambient Temperature with

 

Power Applied

–55°C to +125°C

Supply Voltage to Ground Potential

–0.5V to +7.0V

DC Voltage Applied to Outputs

 

in High-Z State

–0.5V to +7.0V

DC Input Voltage

–0.5V to +7.0V

DC Program Voltage

4.5 to 5.5V

Current into Outputs

16 mA

Static Discharge Voltage

> 2001V

(per MIL-STD-883, Method 3015)

 

Latch-up Current

> 200 mA

Operating Range[2]

Range

Ambient Temperature[2]

Junction Temperature

Output Condition

V

V

CCO

 

 

 

 

CC

 

Commercial

0°C to +70°C

0°C to +90°C

5V

5V ± 0.25V

5V ± 0.25V

 

 

 

 

 

 

 

 

 

 

3.3V

5V ± 0.25V

3.3V

± 0.3V

 

 

 

 

 

 

Industrial

–40°C to +85°C

–40°C to +105°C

5V

5V ± 0.5V

5V ± 0.5V

 

 

 

 

 

 

 

 

 

 

3.3V

5V ± 0.5V

3.3V

± 0.3V

 

 

 

 

 

 

Military[3]

–55°C to +125°C

–55°C to +130°C

5V

5V ± 0.5V

5V ± 0.5V

 

 

 

3.3V

5V ± 0.5V

3.3V

± 0.3V

 

 

 

 

 

 

 

5.0V Device Electrical Characteristics Over the Operating Range

Parameter

Description

Test Conditions

Min.

Typ.

Max.

Unit

VOH

Output HIGH Voltage

VCC = Min.

IOH = –3.2 mA (Com’l/Ind)[4]

2.4

 

 

V

 

 

 

IOH = –2.0 mA (Mil)[4]

2.4

 

 

V

VOHZ

Output HIGH Voltage with

VCC = Max.

IOH = 0 A (Com’l)[6]

 

 

4.2

V

 

Output Disabled[5]

 

 

 

 

 

 

 

 

IOH = 0 A (Ind/Mil)[6]

 

 

4.5

V

 

 

 

IOH = –100 A (Com’l)[6]

 

 

3.6

V

 

 

 

IOH = –150 A (Ind/Mil)[6]

 

 

3.6

V

VOL

Output LOW Voltage

VCC = Min.

IOL = 16 mA (Com’l/Ind)[4]

 

 

0.5

V

 

 

 

IOL = 12 mA (Mil)[4]

 

 

0.5

V

VIH

Input HIGH Voltage

Guaranteed Input Logical HIGH Voltage for all Inputs[7]

2.0

 

VCCmax

V

VIL

Input LOW Voltage

Guaranteed Input Logical LOW Voltage for all Inputs[7]

–0.5

 

0.8

V

IIX

Input Load Current

VI = GND OR VCC, Bus-Hold Disabled

–10

 

10

A

IOZ

Output Leakage Current

VO = GND or VCC, Output Disabled, Bus-Hold Disabled

–50

 

50

A

IOS

Output Short Circuit Current[5, 8]

VCC = Max., VOUT = 0.5V

 

–30

 

–160

mA

IBHL

Input Bus-Hold LOW

VCC = Min., VIL = 0.8V

 

+75

 

 

A

 

Sustaining Current

 

 

 

 

 

 

IBHH

Input Bus-Hold HIGH

VCC = Min., VIH = 2.0V

 

–75

 

 

A

 

Sustaining Current

 

 

 

 

 

 

IBHLO

Input Bus-Hold LOW

VCC = Max.

 

 

 

+500

A

 

Overdrive Current

 

 

 

 

 

 

IBHHO

Input Bus-Hold HIGH

VCC = Max.

 

 

 

–500

A

 

Overdrive Current

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

2.Normal Programming Conditions apply across Ambient Temperature Range for specified programming methods. For more information on programming the Ultra37000 Family devices, please refer to the Application Note titled “An Introduction to In System Reprogramming with the Ultra37000.”

3.TA is the “Instant On” case temperature.

4.IOH = –2 mA, IOL = 2 mA for TDO.

5.Tested initially and after any design or process changes that may affect these parameters.

6.When the I/O is output disabled, the bus-hold circuit can weakly pull the I/O to above 3.6V if no leakage current is allowed. Note that all I/Os are output disabled during ISR programming. Refer to the application note “Understanding Bus-Hold” for additional information.

7.These are absolute values with respect to device ground. All overshoots due to system or tester noise are included.

8.Not more than one output should be tested at a time. Duration of the short circuit should not exceed 1 second. VOUT = 0.5V has been chosen to avoid test problems caused by tester ground degradation.

Document #: 38-03007 Rev. *E