156 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
Example
racadm getconfig -g idRacInfo
# idRacType=8
# idRacProductInfo=Chassis Management Controller
# idRacDescriptionInfo=This system component provides
a complete set of remote management functions for
blade servers
# idRacVersionInfo=P21
# idRacBuildInfo=200708301525
# idRacName=CMC-1
cfgLanNetworking
This group contains parameters to configure iDRAC6 or CMC NIC.
One instance of the group is allowed. Some objects in this group may require
iDRAC6 NIC to be reset, which may cause a brief loss in connectivity. Objects
that change iDRAC6 NIC IP address settings closes all active user sessions
and require users to reconnect using the updated IP address settings.
NOTE: For CMC, use this object with the config or getconfig subcommands.
NOTE: To use this object property for CMC, you must have Chassis Configuration
Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash
sign (#) in the output. To modify a configurable object, use the -o option.
NOTE: For any network property changes on iDRAC6 to be successfully executed
through RACADM, you must first enable iDRAC6 NIC.
The following sections provides information about the objects in the
cfgLanNetworking group.

cfgNicIPv4Enable (Read/Write)

Description Enables or disables iDRAC6 or CMC IPv4 stack.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1