Example

racadm getredundancymode Redundant

getsel

NOTE: To use this subcommand, you must have Login to iDRAC permission.

Subcommand

Description

 

 

getsel

The getsel subcommand display all sensor event log entries in the

 

DRAC.

 

 

Synopsis

racadm getsel -i[-A]

racadm getsel [-s <start>] [-c <count>] [-A] [-o] [-E] [-R] [--more]

NOTE: If no arguments are specified, the entire log is displayed.

The following getsel options (without the -ioption) are used to read entries. Table 2-21describes the getsel subcommand options.

Table 2-21. getsel Subcommand Options

Option

Description

 

 

-A

Specifies output with no display headers or labels.

 

 

-c

Provides the number of records to be displayed.

 

 

-o

Displays each entry in the SEL in a single line.

 

 

-s

Specifies the starting record used for the display.

 

 

-E

Displays RAW SEL data with the other data for each entry.

 

 

-R

Displays only RAW SEL data for each entry.

 

 

-i

Displays the number of entries in the SEL.

 

 

--more

Displays one screen at a time and prompts the user to continue (similar to

 

the UNIX more command).

 

 

RACADM Subcommand Details

89

Page 89
Image 89
Dell CMC 3.2, IDRAC6 1.95, IDRAC6 3.5 manual Getsel, getsel Subcommand Options Description, More

IDRAC6 1.95, CMC 3.2, IDRAC6 3.5 specifications

Dell's Integrated Dell Remote Access Controller (iDRAC) has been a pivotal technology for remote server management, and versions like iDRAC6 3.5 and iDRAC6 with firmware 1.95 have significantly enhanced the capabilities of server management solutions. These integrated management tools focus on improving system performance and uptime for data centers and enterprises.

The iDRAC6 3.5 version comes packed with advanced features that allow administrators to manage servers from anywhere in the world. It supports a web-based interface that provides a comprehensive view of system health, alerts, and logs to facilitate efficient monitoring and management. One significant aspect of iDRAC6 is its ability to provide out-of-band management, allowing IT professionals to access and control servers without relying on the operating system. This feature is crucial for troubleshooting hardware issues or performing system reboots in case of failures.

Another key feature of iDRAC6 3.5 is its Virtual Console capabilities, enabling remote interaction via a browser-based interface. This allows users to perform operations as if they were physically present at the server, including BIOS updates and firmware upgrades. Security is paramount with iDRAC, and version 3.5 includes enhanced security protocols ensuring that access is restricted and that communication remains encrypted.

The Chassis Management Controller (CMC) 3.2 provides integrated management for multiple servers, simplifying monitoring and management within modular systems. It facilitates consolidated management of multiple iDRACs, streamlining tasks such as firmware updates and network configuration across an entire rack of servers. CMC also boasts features like environmental monitoring and alarm notifications, allowing for quicker responses to potential hardware issues.

Furthermore, the iDRAC6 1.95 firmware enhances the functionality offered by previous versions. It includes improved user interfaces for better usability, along with enhanced capabilities for managing power and thermal configurations. With intelligent power management, server administrators can optimize power consumption and cooling, leading to cost savings and reduced environmental impact.

Together, iDRAC6 3.5, CMC 3.2, and iDRAC6 1.95 exemplify Dell's commitment to providing robust and efficient server management solutions. Their features, technologies, and characteristics not only improve operational efficiency but also ensure that organizations can maintain high system availability and performance in an increasingly digital world.