iDRAC6 and CMC Property Database Group and Object Descriptions 279
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY

cfgVFlashPartitionAccessType (Read/Write)

cfgVFlashPartitionAttachState (Read/Write)

cfgLogging
This group is applicable only for iDRAC6 and contains parameters to enable
or disable the OEM event log filtering.
The following section provides information about the objects in the
cfgLogging group:

cfgLoggingSELOEMEventFilterEnable (Read/Write)

Description Indicates the partition access permissions. It configures the access
type to read-write.
Legal Values 0(Read-only)
1(Read-write)
Default 0
Description Displays whether the partition is attached or detached.
Legal Values 1 (Attached)
0 (Detached)
Default 0
Description Enables or disables the SEL Log filtering.
Legal Values 0 (SEL Log filtering is Disabled)
1 (SEL Log filtering is Enabled)
Default 0