iDRAC6 and CMC Property Database Group and Object Descriptions 165
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgRemoteHosts
This group provides properties that allow configuration of the SMTP server
for e-mail alerts.
For CMC, this group enables/disables and configures firmware updates, NTP,
remote syslogging, and SMTP email alerting. Use the -m option to apply this
setting to iDRAC.
NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property for CMC, you must have Chassis Configuration
Administrator privilege.
The following sections provides information about the objects in the
cfgRemoteHosts group.

cfgRhostsFwUpdateTftpEnable (Read/Write)

cfgRhostsFwUpdateIpAddr (Read/Write)

Description Enables or disables iDRAC6 or CMC firmware update from a
network TFTP server.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1
Description Specifies the network TFTP server IPv4 or IPv6 address that is used
for TFTP iDRAC6 or CMC firmware update operations.
Legal Values A string representing a valid IPv4 or IPv6 address. For example,
192.168.0.61
Default For IPv4, it is 0.0.0.0