RACADM Subcommand Details 83
IP Address 15 = ::
LOM Status:
NIC Selection = Dedicated
Link Detected = Yes
Speed = 10Mb/s
Duplex Mode = Half Duplex
NOTE: IPv6 information is displayed only if IPv6 is enabled in iDRAC6.
NOTE: LOM Status is displayed only for iDRAC6 on Rack and Tower servers and is
not displayed for iDRAC6 Enterprise on Blade servers.
getpbinfo
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power = 700 W
Peak System Power = 0 W
Peak System Power Timestamp = 01:08:23 01/27/2009
Minimum System Power = 0 W
Minimum System Power Timestamp = 20:18:30 01/27/2000
Overall Power Health = Not OK
Redundancy = No
System Input Power Cap = 7928 W
Redundancy Policy = None
Dynamic PSU Engagement Enabled = No
System Input Max Power Capacity = 0 W
Input Redundancy Reserve = 0 W
Input Power Allocated to Servers = 0 W
Subcommand Description
getpbinfo Displays power budget status information.