iDRAC6 and CMC Property Database Group and Object Descriptions 227
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgChassisPowerCapF (Read/Write)cfgChassisPowerCapBTU (Read/Write)cfgChassisPowerCapFBTU (Read/Write)
Description Indicates the maximum power consumption limit (in watts) for the
entire chassis. Use cfgChassisPowerCapF when power
consumption is to be changed regardless of whether server
throttling is required. This command generates an error if the value
for this setting is lower than the minimum power required for the
chassis configuration.
Legal Values 2715–16685 watts
Default 16685 watts
Description Indicates the maximum power consumption limit (in BTU/hr) for
the entire chassis. The command generates an error if server
throttling is necessary to achieve the power goal based on the value
for this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
Description Indicates the maximum power consumption limit (in BTU/hr) for
the entire chassis. Use cfgChassisCapFBTU when power
consumption is to be changed regardless of whether server
throttling is required. The command generates an error if the value
for this setting is lower than the minimum power required for the
chassis configuration.
Legal Values 9264 - 56931 BTU/hr
Default 56931 BTU/hr