iDRAC6 and CMC Property Database Group and Object Descriptions 229
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgChassisAllow110VACOperation (Read/Write)cfgChassisMaxPowerConservationMode (Read/Write)cfgChassisPerformanceOverRedundancy (Read/Write)
Description Enables or disables normal chassis power allocations when any
power supply unit is connected to 110V AC service. If disabled and
110V power supplies are detected, all subsequent server power
allocation requests are denied. In this mode additional servers
cannot be powered on, rega rdless of server prio rity.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)
Description Enables or disables max power conservation mode. When enabled,
all servers are immediately reduced to their minimum power levels,
and all subsequent server power allocation requests are denied. In
this mode performance of powered on servers may be degraded, and
additional servers cannot be powered on, regardless of server
priority.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)
Description Enables or disables server performance over power redundancy.
When enabled, this option favors server performance and server
powerup, over maintaining power redundancy. When disabled, the
system favors power redundancy over server performance. When
disabled, then if the power supplies in the chassis do not provide
sufficient power, both for redundancy, as well as full performance,
then some servers may not be granted sufficient power for full
performance, or may not be powered on, in order to maintain
redundancy.
Legal Values 0 (disabled)
1 (enabled)
Default 1 (enabled)