STEP 2 (Continued)
Detect & Measure (Main)
NOTE
If “Caution” is displayed:
Go to “Error messages” (vpage 19), check any related items, and perform the necessary procedures.
If the problem is resolved, return and restart “Audyssey® Auto Setup”.
When performing Audyssey® Auto Setup over againPress ui to select “Retry”, and then press ENTER.
When measuring has stoppedqPress RETURN B, to the “Cancel Auto Setup?” prompt is displayed.
wPress o to select “Yes”, then press ENTER.
Setting up the speakers againRepeat the operation from step 4 of STEP 1 Preparation .
STEP 3
Measure (2nd – 8th)•In STEP 3, you will perform measurements at multiple positions (two to eight positions) other than the main listening position.
•Just one position can be measured but measuring multiple positions increases the accuracy of the correction of acoustic distortion within the listening area.
10Move the setup microphone to position 2, use uito select “Measure”, and then press
ENTER.
The measurement of the second position starts. Measurements can be made in up to eight positions.
Audyssey Auto Setup | MultEQ XT |
Measure (2nd) Please place the microphone at ear height at 2nd listening position.
Measure
Next Calculate
[ENTER] Enter [RETURN] Cancel
If you want to omit measurements from the next position onward, select “Next Calculate”.
(Go to STEP4 Calculate )
11Repeat step 10, measuring positions 3 to 8.
When measurement of position 8 is completed, a “Measurements finished.” message is displayed.
| Audyssey Auto Setup |
| MultEQ XT |
|
|
|
|
|
|
| Measure (Finish) |
|
|
|
| Measurements finished. |
|
|
|
| Retry |
|
|
|
|
|
|
| |
| Next Calculate |
|
|
|
| [ENTER] Enter | [RETURN] Cancel |
| |
|
|
|
|
|
|
|
|
|
|
Set up speakers (Audyssey® Auto Setup)
STEP 4
Calculate12On the STEP 3 screen, use ui to select “Next →
Calculate”, and then press ENTER.
Measuring results are analyzed, and the frequency response of each speaker in the listening room is determined.
Audyssey Auto Setup | MultEQ XT |
Calculate
Now calculating
Please wait
0%
•Analysis takes several minutes to complete. The time required for this analysis depends on the number of speakers connected.
The more connected speakers there are, the longer it takes to perform analysis.
17