Maintenance and Care

WARNING TEMP.. indicator

The WARNING TEMP. indicator shows the state of the function which protects the projector. Check the state of the WARNING TEMP. indicator and the POWER indicator to take proper maintenance.

The projector is shut down and the WARNING TEMP..

Top Control

indicator is blinking red..

 

When the temperature inside the projector reaches a certain level, the projector is automatically shut down to protect the inside of the projector. The POWER indicator is blinking while the projector is being cooled down. When the projector has cooled down sufficiently (to its normal operating temperature), it can be turned on again by pressing the POWER ON/STAND-BY button.

Note:

WARNING TEMP. blinking red

After the temperature inside the projector returns to normal, the WARNING TEMP. indicator still continues to blink. When the projector is turned on again, the WARNING TEMP. indicator stops blinking.

Then check the matters below:

– Did you provide appropriate space for the projector to be ventilated? Check the installing condition to see if ventilation slots are not blocked.

– Is the projector not installed near the ventilation duct of

 

 

 

air-conditioning equipment which may be hot? Install

 

 

 

the projector away from the ventilation duct of air-

 

 

 

conditioning equipment.

 

 

 

– Is the air filter clean? Replace the filter periodically.

 

 

 

(p.52)

 

 

 

The projector is shut down and the WARNING TEMP..

Top Control

indicator emits a red light..

 

 

 

When the projector detects an abnormal condition, it is

 

 

 

automatically shut down to protect the inside and the

 

 

 

WARNING TEMP. indicator becomes red. In this case,

 

 

 

disconnect the AC power cord and reconnect it, and then

 

 

 

 

 

 

 

 

 

turn the projector on once again for check. If the projector

 

 

 

cannot be turned on and the WARNING TEMP. indicator

 

 

 

emits a red light, disconnect the AC power cord and

 

 

 

contact the service station for check and repair.

 

 

 

CAUTION

 

 

 

DO NOT LEAVE THE PROJECTOR WITH THE

 

 

 

AC POWER CORD CONNECTED UNDER THE

 

 

 

ABNORMAL CONDITION. IT MAY RESULT IN

 

 

 

FIRE OR ELECTRIC SHOCK.

 

 

 

WARNING TEMP. lights red

63

Page 63
Image 63
Eiki LC-XS30, LC-XS25 Projector is shut down and the Warning Temp, Indicator is blinking red, Then check the matters below