Hardware Reference Manual
Departmental Switch Model DS-16B
 Copyright 2000 EMC Corporation. All rights reserved
 Departmental Switch Model DS-16B Hardware Reference Manual
 Trademark Information
 FCC Warning USA only
 Departmental Switch Model DS-16B Hardware Reference Manual
 Contents
 Appendix B Switch Support
Chapter Switch Management
Chapter Front Panel Diagnostics
Appendix a Specifications
 Appendix C Error Messages
 Departmental Switch Model DS-16B Hardware Reference Manual
 Figures
 Figures
 Preface
 For Information On See
Related Publications Conventions Used in This Manual
 Ask for Customer Service
Command line arguments when used in text
Examples of specific command entries that you
Arguments used in examples of command line
 Departmental Switch Model DS-16B Hardware Reference Manual
 Introduction System Components
Introduction
 Introduction
DS-16B Switch
Features
Following features
 Ethernet port
Performance
Manageability
Unit may be managed in band or out of band via Telnet, via
 GBICs
System Components
Fabric Operating
System
 Installation
 Unpacking the Switch
 Requirements
Power Requirements
Site Considerations
Cooling
 Fiber Channel
Installation Considerations
To install the adhesive rubber feet
Standalone
 Test Post
Verify Power-On Self
Ethernet
Connection
 Departmental Switch Model DS-16B Hardware Reference Manual
 Switch Management
 SES
Comparing Switch Management Access Methods
 Control Buttons
Managing Through Front Panel Buttons
 Front panel buttons activates the display
Select Menu Configuration Menu
Activating Menu
Display
 Following menus are controlled using the front panel buttons
DS-16B Switch Menus
 Menu Front Panel Telnet Command Default
Commands
Shows the front panel commands and their equivalent
Telnet command
 Unset QuickLoop Port Configure QuickLoop Partner WWN
 Cmem Data Retention Test
 Configuration Menu
Configuration menu See
Ratov Edtov
 Ethernet Subnetmask none
Configuration menu
Ethernet IP address 10
To enter an IP address
 Fibre Channel Subnetmask
To update the Fibre Channel’s IP address
Fibre Channel IP Address
Fibre Channel IP address
 BBcredit
Gateway address
To enter the gateway address
Domain
 Edtov
Ratov Pressing Enter while Ratov is selected, displays
Ratov
Edtov Pressing Enter while Edtov is selected, displays
 Operating modes are determined by the host adapter. The six
Operating Mode
Operating modes for the switch are
For the corresponding operating mode
 VC Multicast
VC Link Ctl
VC Class 2
VC Class 3
 Reset to Default Accept? Yes No
VC Priorities 0,1,2,2,2,2,3,3
Frame Collection Method? Bundle/Piling
 Menu. Pressing Enter while the Operation Menu is selected
Default values
Allows you to select commands
Operation Menu
 Operation Menu Port Disable
Switch Online
Operation Menu Switch Offline
Operation Menu Switch Online
 Reboot Accept? Yes No
Operation Menu Port Enable
Port Enable Accept? Yes No
Operation Menu Reboot
 Status Menu See
Switch Name sw15
Status Menu
Menu is informational only you cannot make changes to
 Current Date Mon Oct 21 102335
Booted At Sat Sep 19 183420
Worldwide Name 1000606900e
Firmware Version
 Up Time Day
Boot Prom Date Jun 12 084829 PST
Powered Time 137 days
Flash Date Jun 12 084829 PST
 Port Throughput 75MB/s
Module TypeL
 3Temperature Sensor Approximate Locations on Motherboard
Temperature 36 34 37 36
 Feb 12 084829 Err SENSOR-FAILED-3
Error Log Selecting Error Log, then pressing Enter, displays
 Test Menu
Licenses
Licenses 01f
 Front Panel Diagnostics
 Overview
Front Panel Diagnostics
Diagnostic
This section gives a diagnostic overview and discusses
 Panel Displays
Diagnostic Front
Fault
Removing Power
 Color and flash speed of each port’s LED, as described
Status and Activity Indicators
Indicators
Front Panel LED Port
 Diagnostics Post
Power-On
 Diagnostic Tests
 Offline Tests Offline & Online Tests
Switch Offline Accept? Yes No
Switch Online Accept? Yes No
System Memory Test at 0x1021d460 len
 0x10199a10 len 13091456 ramTest passed
Related error messages DIAG-MEMORY, DIAG-MEMSZ
Related error messages DIAG-REGERR, DIAG-REGERRUNRST
If the memory tests OK, the front panel displays
 Central MemTest passed
Related error messages DIAG-CMBISTRO, DIAG-CMBISRF
 Port Loopback Test Aborted
Related error messages DIAG-INIT, DIAG-PORTDIED
 SpinSilk Press any button to terminate
 Push Button Test To exit
 Specifications
 General Specifications
Table A-1 shows the switch specifications
Specifications Description
 Table A-2 shows Fabric management specifications
Fabric Management Specifications
 Safety Specifications
Table A-3 Shows Safety specifications
Safety
 Optical Port
Specifications
Switch’s primary operating environments are server rooms
Specification Value
 Table Top Dimensions
Power Supply
Dimensions
Rack Mount Dimensions
 Switch Support
 Support Tool
Switch Support
 Error Messages
 Feb 12
Error Message Formats
Front Panel
Message Formats
 To display error message from the front panel
 Failed test Replace
Diagnostic Error Message Formats
 Error Message
Error Number Test Name Error Name
Numbers
 DIAG-LCMEMTX
DIAG-TIMEOUT
DIAG-CMBISRTO
DIAG-CMBISRF
 DIAG-ERRSTAT 2LONG
DIAG-ERRSTAT Encin
DIAG-ERRSTAT CRC
DIAG-ERRSTAT Trunc
 DIAG-ERRSTAT2LONG
DIAG-ERRSTATENCIN
DIAG-ERRSTATCRL
DIAG-ERRSTATTRUNC
 DIAG-PORTSTOPPED
 Message Description Probable Cause Action
Error Message Tables
 CMI message received failed bad
 DIAG-ERRSTAT
 Asic failure Replace Err#1F26
 Message Description Probable Cause
 FCIU, IUBAD, L, S
FLASH, Badmirror
RPC, Svcexit
RPC, Svcreg
 MQ, QWRITE, L, M
FCIU, IUCOUNT, L, S
FCPH, EXCHBAD, L, S
FCPH, EXCHFREE, L, S
 TIMERS, MSG,LOGWARNING
SYS BADPTR, Logerror
SYS FLASHRD, Logerror
SYS FLASHWR, Logerror
 Logerror
MCAST, Noparentlsr
UCAST, RRTIM, Logcritical
 Sales and Service Locations
 Locations
International Sales
 Departmental Switch Model DS-16B Hardware Reference Manual
 Departmental Switch Model DS-16B Hardware Reference Manual
 Index
 Index
 Departmental Switch Model DS-16B Hardware Reference Manual
 Departmental Switch Model DS-16B Hardware Reference Manual