Cooling air is drawn into the chassis by four fans mounted near the

Requirements

 

rear of the chassis, venting exhausted air through the front of the

 

 

switch.

 

 

 

 

 

 

 

Do not block the front or rear air vents. The switch must have free access to

 

 

ambient air for cooling.

 

 

 

 

 

 

 

 

 

 

Power Requirements

 

Switch power connection is via switched connectors on the switch’s

 

 

front panel, as shown in Figure 2-1. The switch power requirements

 

 

are:

 

 

 

• Properly wired, earth-grounded outlet

 

 

 

• Input voltage: 85 – 265 VAC

 

 

 

• Total power: Up to 155 watts (depending on configuration, see

 

 

Appendix A, Specifications)

 

 

 

• Input line frequency: Nominally 47 to 63 Hz

 

 

 

The switch has an autoranging power supply that automatically

 

 

accepts voltages and line frequencies within its range. A green power

 

 

on indicator light is above the power switch.

 

 

Power Supply 2

Power Supply 1

Figure 2-1Model DS-16B with Two Power Supplies

The switch meets IEC 801-5 surge voltage requirements, however, there is no other provision for surge protection built into the switch’s power supplies. An installation should include normal provisions to assure clean power.