Error Messages

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

DIAG-ERRSTAT

 

Port Error Statistics counter is non-zero,

ASIC, mainboard,

Replace

Err#2640-2647, 3040-3047, 3840-3847

meaning an error was detected when

GBIC module or

mainboard

[portLoopbackTest, crossPortTest,

 

receiving frames.

fiber cable failure

assembly, GBIC

 

One of the following status errors

 

module or fiber

spinSilk]

 

 

 

 

occurred.

 

cable

 

 

Enc_in – Encoding error, inside frame

 

 

 

 

CRC_err – Cyclic redundancy check on

 

 

 

 

frame failed

 

 

 

 

TruncFrm – Truncated frame

 

 

 

 

FrmTooLong – Frame too long

 

 

 

 

BadEOF – Bad end of file

 

 

 

 

Enc_out – Encoding error, outside frame

 

 

 

 

BadOrdSet – Bad symbol on fiber-optic

 

 

 

 

cable

 

 

 

 

DiscC3 – Discarded Class 3 frames

 

 

 

 

 

 

 

DIAG-INIT

 

Port failed to go active in the loopback

ASIC, mainboard,

Replace

Err#264F, 304F, 384F

 

mode requested.

GBIC module or

mainboard

[portLoopbackTest, crossPortTest,

 

 

fiber cable failure

assembly, GBIC

 

 

 

module or fiber

spinSilk]

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

DIAG-INTNIL

 

ASIC failed to get a CMI error (interrupt)

ASIC failure

Replace

Err#2031

 

 

 

mainboard

[cmiTest]

 

 

 

assembly

 

 

 

 

 

 

 

 

 

DIAG-INTNOTCLR

 

The interrupt bit could not be cleared.

ASIC failure

Replace

Err#102C

 

 

 

mainboard

[centralMemoryTest]

 

 

 

assembly

 

 

 

 

 

 

 

 

 

DIAG-LCMEM

 

Data read from the Central Memory

ASIC failure

Replace

Err#1027

 

location did not match data previously

 

mainboard

[centralMemoryTest,

 

written into the same location

 

assembly

 

 

 

 

cmemRetentionTest]

 

 

 

 

 

 

 

 

 

DIAG-LCMEMTX

 

Central Memory transmit path failure:

mainboard failure

Replace

Err#1F27, 1028

 

ASIC 1 failed to read ASIC 2 via the

 

mainboard

[centralMemoryTest]

 

transmit path

 

assembly

 

 

 

 

 

 

 

 

 

DIAG-LCMRS

 

Central Memory Read Short: M bytes

ASIC failure

Replace

Err#1F25, 1025

 

requested but got less than M bytes

 

mainboard

[centralMemoryTest,

 

 

 

assembly

 

 

 

 

cmemRetentionTest]

 

 

 

 

 

 

 

 

Departmental Switch Model DS-16B Hardware Reference Manual

 

 