Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-4

System Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FABRIC, NO_ALIASID, LOG_WARNING

No free multicast alias

Too many multicast

Remove some of the

 

 

 

 

 

 

 

 

 

groups in use

groups.

 

 

 

 

 

 

 

 

 

 

 

 

 

FABRIC, BADILS, LOG_WARNING

 

Bad ISL-ELS size

The ISL-ELS

Contact customer support

 

 

 

 

 

 

 

 

 

payload is wrong.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLASH, BAD_MIRROR,

 

The system’s flash memory has

OS error

The system attempts to

 

 

 

 

 

LOG_WARNING

 

encountered an error.

 

recover from its mirrored

 

 

 

 

 

 

 

 

 

backup. Contact customer

 

 

 

 

 

 

 

 

 

support.

 

 

 

 

 

 

 

 

 

 

 

 

 

RPC, SVC_EXIT

 

An RPC service daemon has

OS error

Contact customer support.

 

 

 

 

 

 

 

terminated prematurely or

 

 

 

 

 

 

 

 

 

unexpectedly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPC, SVC_REG

 

An RPC service daemon could

OS error

Contact customer support.

 

 

 

 

 

 

 

not establish service for a

 

 

 

 

 

 

 

 

 

particular protocol handler.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP, 1_FAILED, LOG_WARNING

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP, 2_FAILED, LOG_ERROR

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP, 3_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP, 4_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP, 5_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 1_FAILED, LOG_WARNING

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 2_FAILED, LOG_ERROR

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 3_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 4_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 5_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FANS, 6_FAILED, LOG_CRITICAL

 

Switch overheated

Fan Failure

Contact customer support.

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER, 1_FAILED, LOG_CRITICAL

Switch Power Failure

Power Supply

Contact customer support.

 

 

 

 

 

 

 

 

 

Failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER, 2_FAILED, LOG_CRITICAL

Switch Power Failure

Power Supply

Contact customer support.

 

 

 

 

 

 

 

 

 

Failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCIU, IUBAD, L, S

 

Invalid IU

OS error

Contact customer support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message Tables

Page 87
Image 87
EMC DS-16B manual FLASH, Badmirror, RPC, Svcexit, RPC, Svcreg, Fciu, Iubad, L, S