R_A_TOV Pressing <Enter> while R_A_TOV is selected, displays:

R_A_TOV: 10000

Resource Allocation Time Out Value (R_A_TOV) is adjustable in 1-second increments using front panel controls, but its value is displayed in milliseconds. This variable works with the variable E_D_TOV to determine the switch’s actions when presented with an error condition. Allocated circuit resources with detected errors are not released until the time value has expired. If the condition is resolved prior to the timing out, the internal time out clock resets and waits for the next error condition.

The range is 1 to 120 seconds.

The set value must be larger than the set value for the Error Detect Time Out Value.

E_D_TOV Pressing <Enter> while E_D_TOV is selected, displays:

E_D_TOV: 2000

E_D_TOV (Error Detect Time Out Value) is adjustable in 1-second increments using the front panel controls, but its value is displayed in milliseconds.

Use the flashSet command during a Telnet session to set the E_D_TOV or

R_A_TOV value (in milliseconds) for values other than whole seconds.

This timer is used to flag a potential error condition when an expected response is not received (an acknowledgment or reply in response to packet receipt, for example) within the set time limit. If the time for an expected response exceeds the set value, then an error condition is met.

The range is 1 to 60 seconds.

The set value must be less than the set value for the Resource Allocation Time Out Value.