Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-LCMTO

 

Central Memory Timeout: Data transfer

ASIC failure

Replace

 

 

 

 

 

Err#1F26, 1026

 

initiated did not complete within the

 

mainboard

 

 

 

 

[centralMemoryTest,

 

timeout period.

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cmemRetentionTest]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMNULL

 

Test failed to malloc.

mainboard failure

Replace

 

 

 

 

 

Err#0112

 

 

 

 

mainboard

 

 

 

 

[ramTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMSZ

 

Memory size to be tested is less than or

mainboard failure

Replace

 

 

 

 

 

Err#0111

 

equal to zero

 

mainboard

 

 

 

 

[ramTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMORY

 

Data read from RAM location did not

CPU RAM failure

Replace

 

 

 

 

 

Err#0110

 

match previously written data into same

 

mainboard

 

 

 

 

[ramTest]

 

location

 

assembly or

 

 

 

 

 

 

 

 

DRAM module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTABSENT

 

Port is not present

ASIC or mainboard

Replace

 

 

 

 

 

Err#2670, 3070, 3870

 

 

 

failure

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest,

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

spinSilk]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTDIED

 

Port was in loopback mode and then went

ASIC, GBIC module

Replace

 

 

 

 

 

Err#265F, 305F, 385F

 

inactive

or fiber cable failure

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest,

 

 

 

 

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

spinSilk]

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTSTOPPED

 

Port is no longer transmitting, as indicated

ASIC, GBIC module

Replace

 

 

 

 

 

Err#3874

 

by the Number Of Frames Transmitted

or fiber cable failure

mainboard

 

 

 

 

[spinSilk]

 

counter being stuck at N frames.

 

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTWRONG

 

Frame erroneously received by port M

ASIC failure

Replace

 

 

 

 

 

Err#3078

 

instead of the intended port N

 

mainboard

 

 

 

 

[crossPortTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-POST_SKIPPED

 

POST is skipped. It’s message

Informational Only

None required

 

 

 

 

 

Err# 0004

 

recommended that POST be executed.

 

 

 

 

 

 

 

[switch initialization]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-REGERR

 

Data read from ASIC register or ASIC

ASIC failure

Replace

 

 

 

 

 

Err#0B15, 0415

 

SRAM did not match data previously

 

mainboard

 

 

 

 

[portRegTest, sramRetentionTest]

 

written into same location

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message Tables

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 85
Image 85
EMC DS-16B manual Asic failure Replace Err#1F26