Front Panel Diagnostics
Pressing <Enter> while Central Memory Test is selected displays a reminder to take the switch offline, if it is not offline. If the message is displayed, take the switch offline.
If the switch passes the test, Passed is displayed:
Central MemTest: passed
Related error messages: DIAG-CMBISTRO, DIAG-CMBISRF,
CMI Test The cmiTest verifies that control messages can be correctly sent from any ASIC to any ASIC. It also tests that the checksum check is ok. The switch must be offline.
Related error messages:
SRAM Retention Test The sramRetentionTest verifies that data written into the ASIC memories are retained and that data bits do not “drop” when read after some amount of delay since the write. The switch must be offline.
Related error messages: DIAG-REGERR, DIAG-REGERR_UNRST,
DIAG-BUS_TIMEOUT
cmemRetention Test The cmemRetentionTest verifies that data written into the SRAMs that make up the central memory are retained and that data bits do not “drop” when read after some amount of delay since the write. The switch must be offline.
Related error messages: DIAG-LCMEM, DIAG-LCMRS,
DIAG-LCMTO
CAM Test The camTest verifies that the SID translation required by QuickLoop and implemented using content addressable memories (cam) are functioning correctly. The switch must be offline.
Related error messages:
DIAG-XMIT
Diagnostic Tests