Safety Specifications
Specifications
Optical Port
Specifications Fibre Channel interfaces of a DS-16B switch equipped with an optical
port interface uses a short wavelength (780 to 850 µm.) or long
wavelength (1270 to 1350 µm) laser transmitter. The laser complies
with 21 CFR(J) Class 1 laser safety requirements. It uses Non-Open
Fibre Control (OFC) Optical GBICs in the circuit. Safe Class 1
operation is guaranteed by limiting optical power emitted by the
port, thereby eliminating the need for physical shutters. The optical
GBIC uses the duplex-SC connector scheme.
Environmental
Specifications The switchs primary operating environments are server rooms,
network equipment closets, and office environments. The acceptable
environmental ranges for a the switch are shown in Table A-4.
Table A- 4 Environmental Specifications
Specification Value
Temperature (operating) 10×C to 40 ×C
Temperature (non-operating) -35×C to 65 ×C
Operating humidity 5% to 85% noncondensing @ 40×C
Nonoperating humidity 95% RH noncondensing @ 40×C
Operating Altitude 0 to 3 kilometers above sea level
Nonoperating Altitude 0 to 12 kilometers above sea level
Operating shock 5g, 11MS duration, half sine
Nonoperating shock 20g, 11MS duration, sq.wave
Operating vibration 5, 5-500-5Hz@1.0 octave/minute
Nonoperating vibration 10, 5-500-5Hz@1.0 octave/minute