Error Messages

Diagnostic Error Message Formats

If any port fails during a diagnostic test, it is marked BAD in the status display.

To retest a port which has been marked BAD, clear the port and set to OK using the diagClearError (port#) command. This command clears the port status only and does not clear the logs or change the port’s condition. The diagClearError (port#) command should only be used during diagnostic procedures to reset a bad port for retest.

Some messages contain the following abbreviations:

sb = Should Be

er = Bits in error

If you run the portStatsShow or the diagShow command prior to running a test, errors may appear as a result of the normal synchronization process. These errors should be addressed if the number of errors found increases

 

when running the

portStatsShow command again.

 

Running any of the tests discussed in “Front Panel Test Menu” clears the

 

accumulated errors before the test is run.

 

 

 

 

Table C-1

Probable Failure Actions

 

 

 

 

 

 

Failed test

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

ramTest

 

 

DRAM module or mainboard assembly

 

 

 

 

 

 

portRegTest

 

 

mainboard assembly

 

 

 

 

 

 

centralMemoryTest

 

 

mainboard assembly

 

 

 

 

 

 

cmiTest

 

 

mainboard assembly

 

 

 

 

 

 

cmemRetentionTest

 

 

mainboard assembly

 

 

 

 

 

 

sramRetentionTest

 

 

mainboard assembly

 

 

 

 

 

 

camTest

 

 

mainboard assembly

 

 

 

 

 

 

portLoopbackTest

 

 

rmainboard assembly

 

 

 

 

 

 

crossPortTest

 

 

mainboard assembly, GBIC or fiber cable

 

 

 

 

 

 

spinSilk

 

 

mainboard assembly, GBIC or fiber cable

 

 

 

 

 