Error Message Tables
Error Messages
DIAG-CMICKSUM
Err#2036
[cmiTest]
CMI message received failed bad
checksum test.
ASIC or mainboard
failure
Replace
mainboard
assembly
DIAG-CMIDATA
Err#2035
[cmiTest]
CMI data received did not match data
transmitted
ASIC or mainboard
failure
Replace
mainboard
assembly
DIAG-CMIINVCAP
Err#2034
[cmiTest]
Unintended ASIC erroneously got CMI
capture flag
ASIC or mainboard
failure
Replace
mainboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
CMI intended receiver ASIC failed to get
CMI capture flag.
ASIC or mainboard
failure
Replace
mainboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI message from
ASIC to ASIC failed.
ASIC failure Replace
mainboard
assembly
DIAG-CMNOBUF
Err#1029
[centralMemoryTest]
Port could not get any buffer ASIC failure Replace
mainboard
assembly
DIAG-DATA
Err#266E, 306E
[portLoopbackTest, crossPortTest]
Payload received by port did not match
payload transmitted.
mainboard, GBIC
module or fiber
cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
Table C- 3 Diagnostic Error Messages (continued)
Message Description Probable Cause Action