Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMICKSUM

 

CMI message received failed bad

ASIC or mainboard

Replace

 

 

 

 

 

Err#2036

 

checksum test.

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMIDATA

 

CMI data received did not match data

ASIC or mainboard

Replace

 

 

 

 

 

Err#2035

 

transmitted

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMIINVCAP

 

Unintended ASIC erroneously got CMI

ASIC or mainboard

Replace

 

 

 

 

 

Err#2034

 

capture flag

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMINOCAP

 

CMI intended receiver ASIC failed to get

ASIC or mainboard

Replace

 

 

 

 

 

Err#2033

 

CMI capture flag.

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMISA1

 

An attempt to send a CMI message from

ASIC failure

Replace

 

 

 

 

 

Err#2032

 

ASIC to ASIC failed.

 

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMNOBUF

 

Port could not get any buffer

ASIC failure

Replace

 

 

 

 

 

Err#1029

 

 

 

 

mainboard

 

 

 

 

[centralMemoryTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-DATA

 

Payload received by port did not match

mainboard, GBIC

Replace

 

 

 

 

 

Err#266E, 306E

 

payload transmitted.

module or fiber

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest]

 

 

 

cable failure

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message Tables

Page 83
Image 83
EMC DS-16B manual CMI message received failed bad