Error Messages

 

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

 

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-REGERR_UNRST

 

Port failed to unreset.

 

ASIC failure

 

Replace

 

Err#0B16, 0416

 

 

 

 

 

 

mainboard

 

[portRegTest, sramRetentionTest]

 

 

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-STATS

 

Port counter value did not match the

 

ASIC, GBIC module

Replace

 

Err#2660-2662, 3060 - 3062

 

number of frames actually transmitted.

or fiber cable failure

mainboard

 

[portLoopback Test, crossPortTest]

 

Possible counters reporting:

 

 

 

assembly, GBIC

 

 

FramesTx - number of frames transmitted

 

 

module or fiber

 

 

 

 

 

 

 

 

FramesRx - number of frames received

 

 

cable

 

 

 

 

 

 

 

 

 

Cl3FrmRx - number of Class 3 frames

 

 

 

 

 

 

received

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-TIMEOUT

 

For portLoopbackTest and crossPortTest:

ASIC, GBIC module

Replace

 

Err#266F, 306F, 386F

 

Port failed to receive frame within timeout

or fiber cable failure

mainboard

 

[portLoopbackTest, crossPortTest,

 

period

 

 

 

assembly, GBIC

 

centralMemoryTest]

 

For centralMemoryTest:

 

 

 

module or fiber

 

 

 

 

 

cable

 

 

 

Port failed to detect an interrupt within the

 

 

 

 

 

 

 

 

 

 

 

timeout period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-XMIT

 

Port failed to transmit frame

 

ASIC failure

 

Replace

 

Err#2271, 2671, 3071, 3871

 

 

 

 

 

 

mainboard

 

[portLoopbackTest, crossPortTest,

 

 

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

spinSilk, camTest]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-4

System Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

 

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIG CORRUPT

 

The switch configuration

 

OS error

The system automatically

 

 

 

information has become

 

 

 

resorts to the default

 

 

 

irrevocably corrupted.

 

 

 

configuration settings.

 

 

 

 

 

 

 

 

CONFIG OVERFLOW

 

The switch configuration

 

OS error

Contact customer support.

 

 

 

information has grown too large

 

 

 

 

 

 

 

 

to be saved or has an invalid size.

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIG VERSION

 

The switch has encountered an

 

OS error

The system automatically

 

 

 

unrecognized version of the

 

 

 

resorts to the default

 

 

 

switch configuration.

 

 

 

configuration settings.

 

 

 

 

 

 

 

 

FABRIC, SEGMENTED,

 

Fabric segmented.

 

Incompatible fabric

Reconfigure fabric or

 

LOG_WARNING

 

 

 

parameters/switches

zones.

 

 

 

 

 

 

Conflict zones

 

 

 

 

 

 

 

 

 

 

 

Departmental Switch Model DS-16B Hardware Reference Manual

Page 86
Image 86
EMC DS-16B manual Message Description Probable Cause