Departmental Switch Model DS-16B Hardware Reference Manual
Error Messages
Error Message Tables
TableC-3 Diagnostic Error Messages
Message Description Probable Cause Action
DIAG-BADINT
Err#1030, 2030
[centralMemoryTest, cmiTest]
Port received an interrupt when not
expecting one
ASIC failure Replace
mainboard
assembly
DIAG-BUS_TIMEOUT
Err#0BoF, 4040F
[portRegTest, sramRetentionTest]
ASIC register or ASIC SRAM did not
respond to an ASIC data access
ASIC failure Replace
mainboard
assembly
DIAG-CAMINIT
Err#223B
[camTest]
Port failed to initialize due to one of the
following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback mode
Port is not active
Software operational
setup error or
mainboard failure
Retry, reboot or
replace
mainboard
assembly
DIAG-CAMSID
Err#223C
[camTest]
ASIC failed SID NO translation test. ASIC failure Replace
mainboard
assembly
DIAG-CLEAR_ERR
Err#0001
Ports diag error flag (OK or BAD) is
cleared.
Informational Only None required
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
ASICs Central Memory SRAMs did not
complete the BISR within the timeout
period
ASIC failure Replace
mainboard
assembly
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
ASICs Central Memory SRAMs did not
complete the BISR within the timeout
period
ASIC failure Replace
mainboard
assembly
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
Error detected at the wrong port ASIC failure Replace
mainboard
assembly
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
Port got the wrong CMEM error type ASIC failure Replace
mainboard
assembly