Technical Specifications

Environmental Specifications

Environmental Specifications

Table 10: Environmental Specifications for the Chassis

 

Description

Specification

Temperature, operating within altitude: 0 to 10,000 feet (0 to 3,000 meters)

Temperature, non-operating within altitude: 0 to 40,000 feet (0 to 12,000 meters)

Humidity (RH), noncondensing

Altitude

50 to 95°F (10 to 35°C)

40 to 149°F (40 to 65°C)

Operating: 10-90%, 28°C max. wet bulb

Nonoperating: 5-93%, 38°C max wet bulb

Operating 0 to 10000 feet (0 to 3000 meters) Above 10,000 feet, maximum temperature decreases by 1°C per 1000 feet (~300 meters) above 10,000 feet

Nonoperating 40,000 ft (12,000 m)

Sound Pressure Level

83 dBAat normal operating temperature.

Environmental Conditions and Power Requirement Specifications for Twinax SFP+ Transceivers

Table 11: Environmental Conditions and Power Requirement for the SFP+ Transceiver

Parameter

Symbol

Min.

Max.

Unit

Storage temperature

TS

40

85

°C

Case temperature

TC

0

50

°C

Module supply voltage

VCCT,R

3.1

3.5

V

Cisco UCS 5108 Server Chassis Installation Guide

OL-20035-05

71

Page 83
Image 83
Cisco Systems UCSEZINFRACHSS manual Environmental Specifications, Parameter Symbol Min Max