Overview

Interpreting LEDs

LED

Color

Description

Fan Module

Off

No power to the chassis or the fan module was

 

 

removed from the chassis.

 

Amber

Fan module restarting.

 

Green

Normal operation.

 

Blinking amber

The fan module has failed.

Power Supply

 

 

OK

Off

No power to the slot.

 

Green

Normal operation.

 

Blinking green

AC power is present but the PS is either in

 

 

redundancy standby mode or is not fully seated.

Fail

Off

Normal operation.

 

Amber

Over-voltage failure or over-temperature alarm.

Table 3: I/O Module LEDs

 

 

LED

Color

Description

Body

Off

No power.

 

Green

Normal operation.

 

Amber

Booting or minor temperature alarm.

 

Blinking amber

POST error or other error condition.

Port 1-4

Off

Link down.

 

Green

Link up and operationally enabled.

 

Amber

Link up and administratively disabled.

 

Blinking amber

POST error or other error condition.