Installing and Removing Components

Installing and Removing a Power Distribution Unit (PDU)

Installing and Removing a Power Distribution Unit (PDU)

Caution The Power Distribution Unit should only be replaced by a Cisco certified technician. This section is for reference only.

Caution You can not hot swap a PDU (N01-UAC1). The entire chassis will need to be shut down and all power cords should be unplugged before attempting this procedure.

Installing a PDU

Procedure

Step 1 Hold the PDU module from below, with the captive screws at the top of the module.

Figure 38: Positioning a PDU (N01-UAC1) in the Cisco UCS Server Chassis, AC Version

195360

1

Step 2 Push the PDU module into the chassis until it seats properly. If power supplies are installed, you may need to partially remove them.

Step 3 Tighten the captive screws.

Step 4 If necessary, reseat the power supplies and restart the system to observe LED behavior.

Cisco UCS 5108 Server Chassis Installation Guide

62

OL-20035-05

Page 74
Image 74
Cisco Systems UCSEZINFRACHSS manual Installing and Removing a Power Distribution Unit PDU, Installing a PDU