System Configuration Manual
300510EN, Rev AA
December 2010
5-45
Rosemount Raptor
Section 5. Installing a Raptor Level Gauging System
Local Display Setup
Choose the parameters to be displayed on the integral display panel on the
Rosemount 2410 Tank Hub. The display will alternate between the selected
items at a rate given by the Display Toggle Time.
20. In the Units for Display pane, choose the desired measurement units
from the drop-down lists. These measurement units will be used by the
2410 local display when presenting the various tank variables.
21. In the Display Tanks pane, select check boxes for the tanks that you
want to present in the 2410 integral display.
22. In the Display Tank Parameters pane, choose the tank parameters to be
displayed by checking the appropriate boxes. See Table5-4 below for
more information on available parameters:
Table 5-4. Various Tank
Parameters can be presented
on the 2410 local display
Variab le Description
Level The current product level in the displayed tank.
Distance Distance (ullage) is measured from the Tank Reference point to
the product surface.
Level rate The speed at which the product surface moves when emp tying or
filling the tank.
Signal strength The signal strength of the radar level gauge measurement signal.
Free water level Water surface level at the bottom of the tank. Available when a
water level sensor is installed in the tank.
Vapor pressure Tank vapor pressure.
Liquid pressure Product liquid pressure.
Air pressure Ambient air pressure.
Air temperature Ambient air temperature.
Vapor temperature Tank vapor temperature.
Product temperature Average temperature of the product.
Tank temperature Average temperature of product and vapor in the tank.