System Configuration Manual

Rosemount Raptor

300510EN, Rev AA December 2010

To configure the FCU Slave Database:

a.Select a free database position (1A, 2A ...) for the level gauge device to be configured.

b.Choose Slave type=2410 Level.

The corresponding Slave Database position (1B, 2B ...) for temperature transmitters and other auxiliary tank devices is automatically assigned to Slave Type=2410 Temp.

c.Enter Modbus addresses for level gauges and auxiliary tank devices (ATD). Ensure that the same database positions, .i.e.

1A/1B, 2A/2B and so on, are used for level gauges and ATDs on the same tank.

d.Select the communication fieldbus (FB1, FB2, FB3, FB4) that the Rosemount 2410 is connected to. Normally there are four fieldbus ports available on the 2160 Field Communication Unit. The RS485 bus is the standard fieldbus interface for a Rosemount 2410 Tank Hub connected to a Rosemount 2160 FCU.

e.If temperature elements are installed in the tank, type the number of elements in the Temp column.

The 2160 Slave Database and the 2410 Tank Database

In a typical Raptor system a Rosemount 2160 FCU collects measurement data from a number of tanks via one or more Rosemount 2410 Tank Hubs. The Modbus addresses of the field devices on the tank need to be stored in the 2160 FCU slave database as well as in the Rosemount 2410 tank database for proper communication with the control room PC.

Level Gauge Modbus Address - 2410 Level

The 2410 Level address field in the 2160 FCU slave database is used for level gauges such as the Rosemont 5900S. This address also needs to be stored in the 2410 tank database as the Level Modbus address. This is normally done as part of the installation procedure of the Rosemount 2410 as described in chapter “Installing a Rosemount 2410 Tank Hub” on page 5-38.

ATD Device Modbus Address - 2410 Temp

The 2410 Temp Modbus address in the 2160 FCU slave database is used for all devices on a tank except level gauges. This address also needs to be stored in the ATD Modbus address field of the 2410 tank database. This is normally done as part of the installation procedure of the Rosemount 2410 as described in chapter “Installing a Rosemount 2410 Tank Hub” on page 5-38.

The first tank in the 2410 tank database uses the Modbus address of the 2410 Tank Hub itself as the ATD Modbus address. Tank number two, three etc. use separate ATD Modbus addresses. The 2410 Modbus address is automatically set as the ATD Modbus address for tank position 1 in the 2410 Tank Database as illustrated in Figure 5-5 on page 5-34.

It is recommended that address range 1 to 99 is used for level gauges and 101 to 199 for ATD devices.

See “Examples of 2160 FCU Slave Database Configuration” on

page 5-32for further information on how to configure the Slave Database of the 2160 Field Communication Unit (FCU) and the Tank Database of the Rosemount 2410 Tank Hub.

5-30

Section 5. Installing a Raptor Level Gauging System

Page 66
Image 66
Emerson 300510EN configurationmanual Slave Database and the 2410 Tank Database, Level Gauge Modbus Address 2410 Level

300510EN specifications

The Emerson 300510EN is a remarkable product designed to meet the evolving needs of industrial automation. Known for its robust performance and advanced features, it has become an integral component in various industries, ensuring optimal efficiency and reliability in operations.

At the core of the Emerson 300510EN is its high-performance processing capability. It is equipped with an advanced microprocessor that allows for rapid data processing and seamless integration with existing systems. This ensures real-time monitoring and control, enabling companies to make informed decisions quickly and effectively.

One of the standout features of the Emerson 300510EN is its user-friendly interface. The device incorporates a touchscreen display, providing operators with intuitive access to critical information. This simplifies navigation through various functions and settings, enhancing user experience and reducing the risk of errors during operation.

In terms of connectivity, the Emerson 300510EN supports multiple communication protocols, including MODBUS, Ethernet/IP, and Profibus. This versatility allows for seamless integration with a wide range of industrial equipment and systems, facilitating enhanced interoperability in complex automation environments. As industries increasingly adopt IoT technologies, the Emerson 300510EN remains adaptable, ensuring businesses can evolve without significant overhauls of their existing setups.

Reliability is another hallmark of the Emerson 300510EN. The device is designed to withstand harsh industrial environments, with robust casing and components that protect against dust, moisture, and temperature fluctuations. This durability minimizes the risks of downtime, ensuring that operations run smoothly.

The Emerson 300510EN also comes equipped with advanced diagnostic features. These built-in capabilities allow for proactive maintenance and troubleshooting, reducing unexpected failures and associated costs. By providing real-time diagnostics, operators can quickly identify issues and implement solutions before they escalate.

Overall, the Emerson 300510EN stands out as a highly effective solution for industrial automation needs. Its blend of advanced processing power, user-friendly design, versatile connectivity, reliability, and proactive diagnostics makes it an invaluable tool for businesses striving to enhance productivity and efficiency in an increasingly competitive marketplace.