Emerson oxymitterdr hazardous area in-siu oxygen probe, ib-106-340cdr Typical System Installation

Models: ib-106-340cdr oxymitterdr hazardous area in-siu oxygen probe

1 66
Download 66 pages 8.96 Kb
Page 17
Image 17

Hazardous Area Oxymitter DR

Instruction Manual

IB-106-340CDR Original Issue January, 2002

1

e.Handling the Hazardous Area Oxymitter DR

The Hazardous Area Oxymitter DR is designed for industrial applications. Treat each component of the system with care to avoid physical damage. Some probe components are made from ceramics, which are susceptible to shock when mishandled.

f.System Considerations

Prior to installing your Hazardous Area Oxymitter DR, make sure you have all the components necessary to make the system installation. Ensure all the components are properly integrated to make the system functional.

NOTE

Retain the packaging in which the Hazardous Area Oxymitter DR arrived from the factory in case any compo- nents are to be shipped to another

site. This packaging has been de- signed to protect the product.

After verifying that you have all the compo- nents, select mounting locations and deter- mine how each component will be placed in terms of available line voltage, ambient temperatures, environmental considera- tions, convenience, and serviceability. A typical system installation is illustrated in Figure 1-2.

Instrument air for reference is optional for most applications. Ambient air will passively diffuse into the inside of the probe in suffi- cient quantity for an accurate measurement. Instrument air is required for applications where the ambient air at the probe location may not contain the typical 20.95% O2. An example would be an installation into a positive pressure flue gas duct which has many leaks into the surrounding air.

If the calibration gas bottles will be perma- nently connected, a blocking valve or check valve is required next to the calibration fit- tings on the termination housing.

GASES

DUCT

STACK

4-20 mA

SIGNAL

OXYMITTER DR

ADAPTER PLATE

AC POWER

EXISTING SIGNAL

CONDITIONING ELECTRONICS

HEATER POWER OXYGEN SIGNAL THERMOCOUPLESIGNAL

INSTRUMENT

AIR SUPPLY

(REFERENCE AIR)

PRESSURE

FLOWMETER REGULATOR

CALIBRATION

GAS

36210004

Figure 1-2. Typical System Installation

Rosemount Analytical Inc. A Division of Emerson Process Management

Description and Specifications 1-3

Page 17
Image 17