Hazardous Area Oxymitter DR
Instruction Manual
1
Table 1-1. Product Matrix
OXT4ACDR Explosion Proof Oxymitter DR In Situ Oxygen Transmitter
Explosion Proof Exchange Probe - Instruction Book
Code Sensing Probe Type
1Ceramic Diffusion Element Probe (ANSI 3 in. 150 lbs)
2Snubber Diffusion Element Probe (ANSI 3 in. 150 lbs)
3Ceramic Diffusion Element Probe (DIN 2572) - 1/4 in. Tube Fittings
4Snubber Diffusion Element Probe (DIN 2572) - 1/4 in. Tube Fittings
5Ceramic Diffusion Element Probe (JIS)
6Snubber Diffusion Element Probe (JIS)
Code Probe Assembly
018 in. (457 mm) Probe
118 in. (457 mm) Probe with 3 ft (0.91 m) Bypass
218 in. (457 mm) Probe with Abrasive Shield(1)
33 ft (0.91 m) Probe
43 ft (0.91 m) Probe with Abrasive Shield(1)
56 ft (1.83 m) Probe
66 ft (1.83 m) Probe with Abrasive Shield(1)
Code Mounting Hardware - Stack Side
0No Mounting Hardware (“0” must be chosen under “Mounting Hardware - Probe Side” below)
1New Installation - Square weld plate with studs
2Mounting to Model 218 Mounting Plate (with Model 218 Shield Removed)
3Competitor’s Mount(2)
Code Mounting Hardware - Probe Side
0No Mounting Hardware
1Probe Only (ANSI) (N. American Std.)
2New Bypass or Abrasive Shield (ANSI)
4Probe Only (DIN) (European Std.)
5New Bypass or Abrasive Shield (DIN)
7Probe Only (JIS) (Japanese Std.)
8New Bypass or Abrasive Shield (JIS)
Code Filtered Customer Termination - NEMA 4X, IP66
11Standard Filtered Termination
12Transient Protected Filtered Termination
OXT4ADR
3
2
1
1
11
Example
HIGH SULFUR SERVICE
For high sulfur applications, please add an additional line item to your purchase order requesting high sulfur cell part number 4847B63G02 in lieu of the standard ZrO2 cell.
Cell replacement kits for high sulfur service are also available.
NOTES:
(1)Recommended usages: High velocity particulates in flue stream, installation within 11.5 ft (3.5 m) of soot blowers or heavy salt cake buildup.
Applications: Pulverized coal, recovery boilers, lime kiln.
(2)Where possible, specify SPS number; otherwise, provide details of the existing mounting plate as follows:
Plate with studs | Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate. |
|
|
Plate without studs | Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories. |
|
|
Rosemount Analytical Inc. A Division of Emerson Process Management | Description and Specifications |