Hardware Preparation and Installation

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

 

 

 

Temperature

0ºC to +40ºC (normal operation) according

-40ºC to +85ºC

 

to NEBS Standard GR-63-CORE

 

 

0ºC to +55ºC (exceptional operation)

 

 

according to NEBS Standard GR-63-CORE

 

 

 

 

Temp. Change

+/- 0.25ºC/min according to NEBS

+/- 0.25ºC/min

 

Standard GR-63-CORE

 

 

 

 

Rel. Humidity

5% to 95% non-condensing according to

5% to 95% non-condensing

 

Emerson-internal environmental

according to Emerson-internal

 

requirements

environmental requirements

 

 

 

Vibration

0.1g from 5 to 100 Hz and back to 5 Hz at

5-20 Hz @ 0.01 g2/Hz

 

a rate of 0.1 octave/minute

20-200 Hz @ -3.0 dB/octave

 

 

 

 

Random 5-20 Hz @ 1 m2/Sec3

 

 

Random 20-200 Hz @ -3 m/Sec2

Shock

Half-sine, 11 m/Sec, 30mSec/sec2

Blade level packaging

 

 

Half-sine, 6 mSec at 180 m/Sec2

Free Fall

 

1,200 mm/all edges and corners

 

 

1.0m (Packaged) per ETSI 300

 

 

019-2-2 (Blade level packaging)

 

 

100mm (unpackaged) per GR-63-

 

 

CORE

 

 

 

2.3.2Power Requirements

The RTM has a typical power dissipation of 22W, and a maximum power dissipation of 30W.