Functional Description
RTM-ATCA-F120-OPT Installation and Use (6806800G29C) 57
4.3 Mezzanine Management Controller
The RTM provides the a Mezzanine Management Controller (MMC) based on the Atmega128L
controller which is compliant to the IPMI v1.5 standard. The MMC is connected to the front
blade's IPMC via IPMB-L.
The MMC provides access to several RTM status sensors that are accessible via IPMI. These
sensors are listed in the following table.
Table 4-1 IPMI Sensors Overview
Sensor Name Sensor Type Sensor Number
Bottom Edge Temp Temperature 0xA2
Ejector State Button / Switch 0x7F
LOS SFP01 Other FRU 0x20
LOS SFP02 Other FRU 0x21
LOS SFP03 Other FRU 0x22
LOS SFP04 Other FRU 0x23
LOS SFP05 Other FRU 0x24
LOS SFP06 Other FRU 0x25
LOS SFP07 Other FRU 0x26
LOS SFP08 Other FRU 0x27
LOS SFP09 Other FRU 0x28
LOS SFP10 Other FRU 0x29
LOS SFP11 Other FRU 0x2A
LOS SFP12 Other FRU 0x2B
Present SFP01 Other FRU 0x10
Present SFP02 Other FRU 0x11
Present SFP03 Other FRU 0x12
Present SFP04 Other FRU 0x13
Present SFP05 Other FRU 0x14
Present SFP06 Other FRU 0x15