Main
Page
TABLE OF CONTENTS
5.0 PIPING CONSIDERATIONSWATER/GLYCOL MODELS ONLY . . . . . . . . . . . . . . . . . . . . . . . 27
FIGURES
TABL ES
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
1.0 GLOSSARY OF SYMBOLS
2.0 PRODUCT DESCRIPTION
2.1 Operational OverviewSelf-Contained, Air Cooled Model
2.2 Operational Overview - Water/Glycol Cooled Model
Figure 3 Component location, rear of XDF
Figure 4 Dimensional data, self-contained, air cooled model
Figure 5 Dimensional data, water/glycol cooled model
Figure 6 Dimensional data, all modelstop, bottom and cable entry cutouts
Caster, 1 of 4
Stabilizing F oot, 1 of 4
3.0 XDF C
3.1 Standard ComponentsSelf-Contained, Air Cooled and Water/Glycol Cooled Models
3.1.1 Frame
3.1.2 Enclosure
3.1.3 Doors
3.1.5 Environmental Control
Heat RemovalSelf-Contained, Air Cooled XDF
Heat RemovalWater/Glycol Cooled XDF
Figure 8 Cooling system componentswater cooled models
RearFront
3.1.6 ControlLieberts iCOM Controller
3.2 Coolant SourceWater/Glycol Models
3.2.1 Closed-Loop Water System
!CAUTION
3.2.2 Drycooler Loop
3.3 Optional Equipment
3.3.1 General Enclosure Options
3.3.2 Power Options MP Advanced Power Strips and Controllers
Uninterruptible Power Supply
4.0 I
4.1 Inspection
Packing Material
4.2 Recommended Setup Equipment
4.3 Unloading the XDF
4.3.1 Handling the Unit While It is Packaged
4.3.2 Unpack the XDF
4.3.3 Removing the XDF from Skid
Four (4) Lag Bolts and Two Brackets Per Corner
Figure 16 Roll XDF off the shipping skid
4.4 XDF Site Preparation
4.5 Voltage Requirements
4.5.1 Voltage Input Requirements
Changing Condenser Fan Power SourceSelf-Contained, Air Cooled Units
4.5.2 Uninterruptible Power SupplyOptional
4.5.3 MP Advanced Power StripsOptional
4.6 Drycooler InstallationWater/Glycol Cooled Model
4.7 Equipment Layout
4.8 Frame and Enclosure Configurations
4.8.1 Internal Mounting Rails
4.8.2 Rear-Mount RailsPosition
4.9 Mounting Hardware
4.10 DoorRemove
4.10.1 Remove the Door
4.10.2 Quick Door Removal
4.11 Side PanelsRemove and Replace
4.11.1 Remove the Left Panel
4.11.2 Remove the Right Panel
4.11.3 Replace a Panel
5.0 PIPING CONSIDERATIONSWATER/GLYCOL MODELS ONLY
5.1 General
5.2 Closed Loop Water System
5.2.1 Expansion Tanks, Fluid Relief Valves and Other Devices
5.2.2 Corrosion Protection
5.2.3 Freeze ProtectionCoolant Type and Insulation
5.3 Drycooler Loop System
5.3.1 Glycol Solutions
6.0 FILLING THE XDF WITH COOLANTWATER OR GLYCOL
6.1 Preparing the System for Filling
6.1.1 XDF Water/Glycol Cooled Unit Volume
6.1.2 Filling the System with Water or Glycol
7.0 ELECTRICAL CONNECTIONS
Electrical Connections
32
Figure 22 Customer electrical connections and cable entry pointswater/glycol cooled units
Move plate to back panel for alternate power cord routing (see also Figure 23)
Customer Cable Entry Points
7.1 Utility Power Supply
7.1.1 Route Input Power Cables Through the XDFs Top
8.0 CABLE MANAGEMENT OPTIONS
8.1 Cable Management Considerations
8.2 Cable Management
8.3 Cable Access
8.3.1 Top Cover and Back
8.4 Optional Cable Management Channel
Figure 26 Cable management mounting locations and options: Velcro cable straps, Cable Spools
Figure 27 Cable management accessories: Cable Tray
Cable Tray Detail View
9.0 S
9.1 XDF Startup Inspection Checklist
9.1.1 Site Conditions
9.2 Starting the XDF
ESC
?
10.0 O
10.1 Environmental Control
Remote CommunicationsBuilding Management Systems, Liebert SiteScan
10.2 iCOM Components and Functions
Table 7 Keyboard icons and functions
?
ESC
10.3 Navigating Through the iCOM Display
OK NO
Figure 31 iCOM simple display default screen components
UNIT 1 UNIT ON
T ACT
11/07130%
100%
11/07
USER MENUS 1/ 6 PASSWORD LEVE L0 ???? SETPOINTS
DISPLAY SETUP U404 TEMP F / C F U405 CONTRAST 50% U406 BUZ FREQ 50%
10.4 Changing Operational Settings
Table 8 User menu icons
C / F % RH SET
1 2 39 6 SET
1234h
1 2 39 6
10.5 Changing iCOMs Display Settings
DISPLAY SETUP U404 TEMP F / C F U405 CONTRAST 50% U406 BUZ FREQ 50%
10.7 Operation With the Door Open
NO
OK
10.8 Backup Ventilation System
10.9 XDF Compressor
10.10 Uninterruptible Power Supply
11.0 M
11.1 Periodic Maintenance
Table 9 Troubleshooting
12.0 S
Figure 36 XDF model numbers
Table 10 Physical specifications
XDFS141010
Table 11 Electrical specifications
Table 12 Total heat rejection
12.1 Optional Power Systems
Table 13 UPS performance data
12.2 Optional Managed Power - Advanced Power Strips, Vertical- or Horizontal-Mount