Chapter 11 Configuring by using the menus
Page 11.2
11.3 Recommended sequence for configuration
It is recommended that you configure items in the following order:
1. Inputs (See Section 11.5).
2. Transducer details (See Section 11.6).
3. Anything else such as Specific Gravity, Energy, Custom Application, Multiview, etc. Do these in the order
in which they appear in this chapter. (See Sections 11.7- 11.18).
Item to be configured Calculations involved (if any) See Section
Analogue inputs - 11.5
Transducer details - 11.6
Transmitter details Line temperature
Densitometer temperature
Atmospheric pressure
Live CO2 and N2
11.7
Flowmeter details Orifice mass and volume flow rate
Turbine mass and volume flow rate
Prime specific gravity
11.8
Flow rate Turbine mass and volume flow rate
Standard volume rate
11.9
Totalisers Totalisation 11.10
Line density Line density
AGA8 density compressibility
Normalisation of gas components
Nx-19 compressibility
Linear interpolation compressibility
SGERG compressibility
Density referral
11.11
Base density Base density
Prime base density
11.12
Specific gravity Specific gravity
Prime specific gravity
11.13
Energy Energy
Energy rate
11.14
Custom application User calculations 1 and 2 11.15
mA outputs mA outputs 11.16
Other parameters - 11.17
Multiview - 11.18