EPSON Stylus Photo 750

Revision A

4.2.1 Housing Removal

Since this printer has no lower housing, the printer mechanism is exposed just by removing the upper housing.

1.Open the printer cover and set the PG adjust lever on the right-hand side to (+) position.

U p p e r H o u s i

2. Remove 4 screws and remove the upper housing.

CH E Pull the front edge of the upper housing while

P O I lifting up the upper housing to remove it.

CA U TBeIcarefulO N not to pinch the cable with the posts of the

upper housing when reinstalling it.

Figure 4-2. Housing Removal

Disassembly and Assembly

Disassembly

54

Page 59
Image 59
Epson Photo750 manual Housing Removal