EPSON Stylus Photo 750

Revision A

2.2.2.3 Sensor Circuit

The following sensor circuits are mounted on the C259 Main Control Circuit.

HP Sensor

HP sensor uses the photo interrupter method. A HP sensor detects the carriage home position. It is used for managing printing position and cleaning, etc.

PE Sensor

PE sensor uses the photo interrupter method. A PE sensor determines if there is a paper in the printer. Based on the signal from this sensor, a particular page edge treatment such as Micro- weave printing is performed.

ASF Sensor

ASF sensor uses the photo interrupter method. An ASF sensor detects the position of return lever when the power is turned on, and causes the paper to be picked up by the pick up roller fro the normal initial position.

Thermistor Sensor (TH)

This sensor is mounted on the print head board and measures the temperature around the head. It keeps stable printing quality, changing PZT drive voltage(VH) slightly according to changes of environmental temperature.

Black/Color Cartridge Sensor(COB/COC)

Cartridge sensor uses the mechanical method. The sensor detects if the cartridge is installed or not.

IC 2

 

 

+5V

ASFV

 

E05B58**

 

 

+5V

GND

CN4

 

 

 

SWA0

97

+5V

ASF

ASF

 

 

 

 

 

+5V

HPV

 

 

 

 

+5V

GND

CN5

SWA1

98

+5V

HP

HP

 

 

 

 

+5V

PEV

 

 

 

 

+5V

GND

CN6

SWA2

99

+5V

PE

PE

 

 

 

SWC0

 

 

COB

 

SWC1

 

 

coc

 

 

 

 

 

GND

 

 

 

 

 

 

CN9

CPU

AN0

 

 

THM

 

 

 

 

 

 

op06

Figure 2-6. Sensor Circuit

Operating Principles

Operating Principles of Electric Circuit

34

Page 39
Image 39
Epson Photo750 manual Sensor Circuit