EPSON Stylus Photo 750

Revision B

5.3.3 Head Voltage ID Adjustment

Since the elements used in the print head differs, it becomes necessary to set the head voltage in appropriate condition so that the amount of discharged ink becomes even. The setting value is determined according to the test result of head characteristics on the production process.

1.Select “Adjustment” on the main menu and press Return key. Program goes to the adjustment menu.

Pr o m p t - S P 7 5 0 A u t o

a 8d j

2.Select “Head Actuator Voltage ID Input” and press Return key. Following screen appears.

Pr o m p t - S P 7 5 0 A u t o

a d j 9

3.Select “Change Data”, then the screen to input the Head ID appears.

4.Input the Head ID (8 digits).

You can find VH voltage ID on the following position:

Print Head:

On the side face of the print head.

Printer mechanism: On the label of the packing box of the printer mechanism.

5.After completing the Head ID input, press ESC key until the screen returns to the adjustment menu.

If you wish to check the head data, select “Check the present data” to check the current head data.

Adjustment

Adjustment by Adjustment Program

83

Page 88
Image 88
Epson Photo750 manual Head Voltage ID Adjustment