4.2.5.12 Cartridge Sensor(Sensor, I/C) Removal

1.Remove one screw securing “Bush Holder, Sensor, I/C” to the carriage assembly, and remove it.

Screw

Bush Holder,

Sensor, I/C

 

Figure 4-26. Bush Holder, Sensor, I/C Removal

2.Remove “Harness, I/C” from the clamp part of the carriage. Harness

Figure 4-27. Removing Harness

3.Release 4 hooks(2 outer hooks, 2 inside hooks), which secure “Holder, Sensor, I/C” with the carriage assembly”, and remove the “Holder, Sensor, I/C” upward.

Carriage Assembly

Engaging Hole

Engaging part of inside hook

Engaging Holes

Outside Hook

Inside Hook

 

 

 

Outside Hook

Holder Sensor, I/C

Figure 4-28. Holder,Sensor, I/C Removal

4.Release 2 hooks of the hook, which secure the sensor to the carriage assembly”, and remove the sensor and harness.