EPSON Stylus Photo 750

Revision A

4.2.5.8 Carriage Assembly Removal

1.Remove the upper housing.(See “Housing Removal” on page -54)

2.Push “Holder, Pulley, Driven” to loosen the timing belt and detach the timing belt from the pulley of CR motor assembly.

3.Take out “Compression Spring, 19.6” from “Holder, Pulley, Driven”.

4.Remove “Pulley, Assembly, Driven” with the timing belt from the “Holder, Pulley Driven”.

5.Move the “Holder, Pulley, Driven” and release the hook, then remove it from the frame.

6.Release the hook and remove the “Lever, PG”.

B U S H , P A R A L L EBLU SA HD ,J UPSATR,A LR LI EG LH TA D J U

S id e f r a m e o f

C u t o u t o f s id e f r a m e p r in t e r m e c h a n is m

7. Release the hook of “Lever, PG, Sub” and remove “Lever, PG, Sub”

 

and spring washer from the edge of the “Shaft, CR, Guide”.

Figure 4-19. Bush Parallel Adjust Removal

8.Remove one screw securing “Bush, Parallel Adjust, Right” from the right frame.

9.Rotate the “Bush, Parallel Adjust, Right” and match it with the cut out of the frame. Then, remove the “Bush, Parallel Adjust, Right”.

Disassembly and Assembly

Disassembly

68

Page 73
Image 73
Epson Photo750 manual Carriage Assembly Removal, Bush Parallel Adjust Removal