Configuring the PathBuilder S200 Series Switch for Bridging Operation

Configuring Translational Bridging

Introduction

 

 

This section explains how to configure your PathBuilder S24x, 26x, and 27x switch

 

to implement the Translational Bridging feature.

What is

 

 

Translational Bridging allows a PathBuilder S24x, 26x, and 27x switch to bridge

Translational

traffic between Ethernet and Token Ring networks. Upon receiving traffic from one

Bridging

network the PathBuilder S24x, 26x, and 27x switch’s Source Route translates the

 

data into a translational bridge format that can be used by the other network.

 

For Translational Bridging to function, several conditions must exist:

 

 

• The Token Ring network must conform to IEEE standard 802.5 and the

 

 

Ethernet network mst conform to 802.3.

 

 

• The PathBuilder S24x, 26x, and 27x switch must contain a 4 Meg FLASH

 

 

and be using one of these software options: Option 71 to 75.

 

 

Note

 

 

 

 

 

 

In a single node, Translational Bridging performance is limited to 350 packets

 

 

per second.

Parameter

 

 

To enable Translational Bridging, you need to set the parameter Link Mode =

 

TRANS (in the Bridge Link Parameters Record). Also, be sure the parameter Virtual

 

Ring Number is set to a unique value.

Configuration

 

 

These factors should be considered when configuring your PathBuilder S24x, 26x,

Guidelines

and 27x switch for Translational Bridging:

 

 

• Only one link in a PathBuilder S24x, 26x, and 27x switch can have the param-

 

 

eter Link Mode = TRANS.

 

 

• Only Bridge Link with Bridge Type = SR can have Link Mode = TRANS.

 

 

• LLC Termination is not supported between Token Ring and Ethernet when

 

 

using Translational Bridging.

 

 

• You can increase the value of the parameter Aging Period (in the Bridge

 

 

Parameters Record) to limit the relearning of the entries in the Translational

 

 

Bridging MAC Address.

 

For more information about configuring a PathBuilder S24x, 26x, and 27x switch for

 

Translational Bridging, refer to the configuration example in the next section.

Configuration

 

 

Figure 18 shows an example of a PathBuilder S24x, 26x, and 27x switch configured

Examples

for Translational Bridging between an Ethernet and Token Ring Network within the

 

same node. The records and parameters that need to be configured for Translational

 

Bridging are shown.

Note

In this example, the parameters in Bridge Link 1 and Bridge Link 2 records remain at their default values. However, to implement the default settings, you need to call up the records (from the CTP) and then save them.

Bridging

37

T0008-16F

Release 5.2M

Page 41
Image 41
EXP Computer S200 manual Configuring Translational Bridging