Configuring the PathBuilder S200 Series Switch for Bridging Operation

Attaching a Station This table describes how a station attaches to a ring. to a Ring

Step

Action

Result/Description

 

 

 

1

The station requests values for the

 

 

ring’s operational parameters from

 

 

the RPS.

 

 

 

 

 

2

An attaching station also sends the

 

 

RPS its adapter software level as

 

 

well as its Upstream Neighbor

 

 

Address.

 

 

 

 

 

 

 

If...

Then...

 

 

 

 

 

 

An RPS is

It responds to

The RPS then notifies the LAN

 

present on the

the station’s

managers that a new station has

 

ring,

request by

attached to the ring.

 

 

sending it the

 

 

 

current values

 

 

 

for the ring’s

 

 

 

operational

 

 

 

parameters.

 

 

 

 

 

 

An RPS is not

The ring station

An RPS has a functional address of

 

present on the

uses the values

C00000000002.

 

ring,

assigned by the

 

 

 

program using

 

 

 

the ring station

 

 

 

or the default

 

 

 

values for its

 

 

 

operational

 

 

 

parameters.

 

 

 

 

 

 

 

 

 

Bridging

47

T0008-16F