LLC2 Local Termination

T1 Reply Timer

Range:

1 to 25 (seconds)

 

 

Default:

1

 

 

Description:

This Ack timer is used by a station to detect a failure of the

 

remote station to acknowledge an outstanding I frame or supervi-

 

sory frame with the pole bit set to 1.

 

 

Boot Type:

Tables and Node Record.

 

 

T2 Rx ACK Timer

 

 

Range:

1 to 255 (tenths of seconds)

 

 

Default:

1

 

 

Description:

Specifies how long the station withholds acknowledgment of a

 

frame from the remote station that requires acknowledgment. This

 

reduces the number of acknowledgments generated by a link

 

station. When the timer expires, the link station immediately sends

 

an acknowledgment for all received frames not yet acknowledged.

 

 

Boot Type:

Tables and Node Record.

 

 

Ti Inactivity Timer

 

 

Range:

2 to 255 (seconds)

 

 

Default:

30

 

 

Description:

The Idle Timer is used by a station to detect an inoperative

 

condition of the logical link. This timer starts when the link is idle

 

(no data to pass and no outstanding acknowledgments). When the

 

timer, expires, the station sends a supervisory frame with the poll

 

bit set to 1.

 

 

Boot Type:

Tables and Node Record.

 

 

N2 Retry Count

 

 

Range:

1 to 20

 

 

Default:

8

 

 

Description:

Specifies the number of times an I frame or supervisory frame

 

with poll bit set to 1 is transmitted due to T1 acknowledgment

 

timeout before the logical link is declared down (inoperative).

 

 

Boot Type:

Tables and Node Record.

 

 

Bridging

111

T0008-16F

Release 5.2M

Page 115
Image 115
EXP Computer S200 manual T1 Reply Timer