Bridge Hardware Components in PathBuilder S200 Series Switches

Bridge Hardware Components in PathBuilder S200 Series Switches

Introduction

This section describes bridge hardware configuration and connections for the

 

PathBuilder S200 series switch.

Bridge

 

Figure 12 shows the physical connections of the modules that provide bridging

Configuration and functionality for PathBuilder S200 series switch. This figure shows a LAN port

Connections

module and supporting WAN Adapter module within a PathBuilder S200 series

 

switch. The LAN port module is broken out into a driver and a forwarder to show the

 

concept of bridge links.

 

At each end node, the bridge has connections referred to as bridge links. Bridge links

 

that connect to the LAN are referred to as LAN bridge links. Bridge links that

 

connect to remote bridges across the WAN are referred to as WAN bridge links.

LAN Link Numbers range from 1 to

4:up to two LAN connections are supported for Ethernet.

 

 

LAN Port Module

 

 

 

 

5

Token

 

1

.

LAN

LAN

.

Ring

Driver

Bridge

.

LAN

 

Forwarder

.

 

 

 

32

Up to 32 WAN links can be defined (numbered 5 to 36), one for each bridge connection over an SVC (PVC for Frame Relay).

WAN

 

 

 

X.25 SVCs connected to

 

 

 

Adaptor

 

 

 

SVCs on network ports

 

 

 

 

(PVCs for Frame Relay)

 

 

 

 

 

 

 

 

 

 

 

Figure 12. LAN Port Module and WAN Adapter Module (Logical View)

 

The LAN port consists of low level drivers and the bridge forwarder. This can be

 

viewed as the functioning bridge. The WAN Adapter is closely associated with the

 

bridge. The WAN Adapter provides the network services that the bridge requires in

 

order to function over the WAN network. The principal service is establishing and

 

maintaining SVC (PVC for Frame Relay) connections to remote LAN bridge

 

forwarders so that virtual circuits can be formed between the forwarders.

 

The bridge sees the LAN and the WAN (by means of the WAN Adapter) as networks

 

it is attached to by links. There are a total of 36 links: four LAN links and 32 WAN

 

links.

LAN Interface

 

The PathBuilder S200 series switch supports only one LAN per node, so only one

Support

link is needed for the LAN port connection: link number 1. The PathBuilder S24x,

 

26x, and 27x switch supports up to two Ethernet LANs per node. See “Dual LAN

 

Ethernet” section on page 117 for more details on this functionality.

 

On the PathBuilder S200 series switch links numbered 2 to 4 are not used and are

 

reserved for future configurations. WAN links are numbered 5 to 36 and provide up

 

to 32 WAN connection links which correspond to potential bridges.

Bridging

17

T0008-16F

Release 5.2M

Page 21
Image 21
EXP Computer S200 manual Bridge, Connections, LAN Interface, Support