NOTES:
• The installation must conform to national and local building and electrical codes, and UL requirements. See the device user guide for details.
• The included power supply MUST NOT be installed above the suspended ceiling, in wall cavities or similar locations.
1. — Install the PMK 550 Base Plate |
a. Using a 5/32 inch hex wrench, remove the four |
cover screws from the center of the PMK 550 |
and slide the two halves apart. Remove them |
from the base plate. |
NOTE: If the PoleVault switcher and its power |
supply are already installed, go directly to |
step 2e. |
b. To mount the PoleVault switcher, place the |
mounting plate, with the raised tabs upwards, |
on top of the switcher top and pass the two |
supplied |
the plate holes and into the top of the switcher |
(see image at right). Secure the plate but do |
not overtighten. |
c. Invert the combined plate and switcher and |
hook the plate tabs into the PMK 550 base |
plate. Secure it to the base plate with two |
screws. |
NOTE: The switcher should be mounted |
on the same side as the base plate’s |
pipe collar. The switcher is secured |
inverted to the base plate so that when |
the plate is turned over and fastened on |
the pole, the device will be in the correct |
orientation |
Use only the supplied screws to avoid damaging the switcher.
d.Attach the associated power supply with the supplied plastic ties, by passing the ties through the appropriate slots and around the power supply. Tighten until snug.
e.Using a 3/32 inch hex wrench loosen the four pipe collar set screws, and slide the plate up the pipe until the base plate is touching the drop ceiling.
f.Level the plate and secure it in place with the four set screws located on the collar, ensuring that a minimum of three set screws are tightened firmly against the pole.
CONFIG | 1 |
2 | INPUT |
| 3SELECTION |
4
|
|
| 5 |
|
|
|
|
|
| AUX | AUDIO | INPUT |
| PVS |
|
|
|
| PEAKAUDIO | MIC |
| ||
|
|
|
| NORMAL | POLEVAULT |
| |
|
|
|
|
| LEVEL | ADJUST | 305SA IP |
|
|
|
| SIGNAL |
| ||
|
|
|
|
| VOICELIFT | PEAK | SWITCHER |
|
|
|
|
| NORMAL | PAGING | |
|
|
|
|
|
| SIGNAL | SENSOR |
| Å | Û |
|
| SENSITIVITY | ||
5 |
|
|
| ||||
AUX AUDIO |
|
|
|
|
ÅPlace the plate (with raised tabs up) on the top of the PVS 305SA IP and secure with supplied screws. Û Hook tabs into base plate.
ÛInvert and secure the PVS 305SA IP and Ü the power supply on the PMK 550 base plate.
†Slide the base plate up onto the pole and °secure with the set screws.
34PoleVault IP Systems • Installation — Stage 4 (PMK 550 and PVS 305SA IP)