RemoteOperation,cont’d

The MAV AV Series switchers can be remotely controlled via the switcher’s rear panel RS-232 connector (figure 4-1) or using an optional infrared small matrix universal remote control (figure 4-2).

 

 

Pin

RS-232

Function

 

 

1

Not used

5

1

2

TX

Transmit data

3

RX

Receive data

 

 

 

 

4

Not used

 

 

5

Gnd

Signal ground

9

6

6

Not used

Female

7

Not used

 

 

8

Not used

 

 

9

Hardwired IR input

Figure 4-1 — Remote connector pinout

 

MUTE

PRESET

9

5

1

 

IR 501 SMALL MATRIX REMOTE

UNMUTE INPUT OUTPUT

SAVE VIDEO AUDIO

0 +10 ENTER

6 7 8

2 3 4

INPUT/OUTPUT SELECTION

Extron

IR 501 Remote, Part # 70-336-01

Figure 4-2 — Small matrix IR remote control

1 2 3

IR

The RS-232 protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control. RS-232 remote control devices can be either a host device, such as a computer or a control system.

When using communications software such as HyperTerminal to control the

MAV switcher, verify that the terminal emulation is set to Auto Detect or

ANSI and set flow control to None. Other settings may cause errors.

Two remote control methods are available: Extron’s Simple Instruction Set and Extron’s Windows-based control program.

Operation of the IR 501 remote control is described in the IR 501 Small Matrix IR Remote Control User’s Guide.

The switcher’s IR receiver is disabled by default and must be enabled to use the IR remote control. See the IR receiver enable SIS command on page 4-7 to enable the IR receiver.

Using the hardwired IR input on pin 9, you can use a control system with IR-learning capabilities to operate the switcher just as if you were using an IR 501 remote control. The control system must first “learn” the IR command from an IR 501, after which, it sends the same commands to the MAV via pin 9.

Simple Instruction Set Control

Host-to-Switcher instructions

The switcher accepts SIS (Simple Instruction Set) commands through the RS-232 port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each switcher response to an SIS command ends with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.

4-2 MAV 44 / 48 / 84 / 88 Matrix Switchers Remote Operation