Fig.7-10

Fig.7-10

ArtNo.132-0001 - 1 phase

50Hz

1-phase 230 VAC 50 Hz

Fig.7-11

ArtNo.132-0003 - Single-phase connections (AUS)

A N

Fig.7-12

ArtNo.132-0002 - 3 phase

50Hz

3-phase3-phase240/415230 V V50 Hz50 Hz

AC

Fig.7-13

Mains terminal

A Fig.7-11 N Fig.7-12

Fixing bracket for

conduit connection

Cable clamp

ArtNo.132-0005 - Fixed wiring connection 2 (AUS)

Conduit

Electrical Connection

This appliance must be installed by a quali￿ed electrician to comply with the relevant regulations (AS/NZS 60335.2.6) and also the local electricity supply company requirements.

Make sure that the mains characteristics (voltage, nominal, power, etc.) match the ratings indicated on the data plate a￿xed to the cooker.

Current Operated Earth Leakage Breakers

The combined use of your cooker and other domestic

appliances may casue nuisance tripping, so we

recommend that the cooker is proctected on an individual RCD (Residual Current Device) or RCBO (Residual Current Breaker with Overload)

IF IN DOUBT, PLEASE CONTACT A SUITABLY QUALIFIED

ELECTRICIAN.

The cooker is preset for a single-phase earthed electrical connection. It is essential to install a multi-pole circuit breaker that completely disconnects the appliance from the mains, with a minimum contact break distance of 3 mm.

nnWARNING: THIS APPLIANCE MUST BE EARTHED.

The appliance must be connected to an e￿cient earthing circuit. If the electricity network is not equipped with an earth connection, then it must be installed separately in compliance with local regulations.

Earthing is a safety measure required by law, and must be performed with particular care by a quali￿ed technician, who must also check that the electricity supply characteristics are correct.

The total electrical load of the appliance is approximately

7.4kW. The cable size used should be suitable for this load and comply with all local requirements.

Access to the mains terminal is gained by removing the electrical terminal cover box on the back panel. Connect the mains cable to the correct terminals for your electrical supply type (Fig.7-10and Fig.7-11). Check that the links are correctly ￿tted and that the terminal screws are tight. Secure the mains cable using the cable clamp.

Fixed Wiring

For connection to ￿xed wiring, i.e. ￿exible conduit, remove the electrical terminal cover box on the back panel. Using the two screws, ￿x the strain relief bracket in position.

Fix the conduit-to-conduit mounting bracket onto the strain relief bracket. Connect the mains cable to the correct terminals for your electrical supply type (Fig.7-12and Fig.7-13). Check that the links are correctly ￿tted and that the terminal screws are tight.

Replace the electric terminal cover box; make sure that the conduit is clear of the bottom ￿ange.

24

Page 26
Image 26
Falcon U108610-07 installation instructions A N, Fixed Wiring, 11, 12, 13, Current Operated Earth Leakage Breakers