9.Reinstall the top cover.

5725A

Instruction Manual

J222

CURRENT AMPLIFIER (A2)

FRONT OUTPUT

CABLE

SECURE UNUSED

CABLE

REAR OUTPUT

CABLE

aq23f.eps

Figure 6-7. Enabling Front or Rear Binding Posts

Caution

Make sure that the unused connector is neatly secured in the recessed area of the chassis side, away from the High Voltage Sense assembly as Figure 6-7 shows. If it is allowed to hang down, shorting can occur.

8.Reconfiguration is complete. Reinstall the Current Amplifier and High Voltage Amplifier assemblies, being careful to correctly seat each assembly into the connector on the Interconnect assembly.