5725A
Instruction Manual
|
| HIGH VOLTAGE |
|
|
| AMPLIFIER |
|
|
| (A3) |
|
|
|
| LED |
| TP307 |
| CR317 |
LED | TP304 |
| TP301 |
CR318 |
|
| |
|
|
| |
|
|
| POWER |
|
| MODE |
|
|
| CURRENTSTANDBY |
|
|
| 5725A |
|
|
| FAULT | FRONT PANEL |
|
| OVERLOADOFF | |
|
|
| |
|
| CABLE |
|
|
| 11A |
|
|
| MAX |
|
|
| 2OV |
|
|
| PK |
|
|
| MAX |
|
|
| POWER SUPPLY | |
|
|
| (A4) |
|
|
| aq16f.eps |
Figure
6.Verify that both LEDs CR317 and CR318 on the Power Supply assembly (A4) are off. If either is lit after three minutes, there is a fault in the high voltage capacitor
Warning
Do not rely on the power supply leds as an indication of the presence of high voltage. Always use a voltmeter to check for high voltage between TP307 and TP301, and between TP307 and TP304.
7.To confirm that high voltage has dissipated, set a DMM to the 1000V dc range, and take a reading with the common lead to TP307 and the high lead to TP301 on the Power Supply assembly. This is the +400V filter capacitor test point, and it should be at a safe level near zero.