SuperTrak66™ User's Manual | Chapter 7 |
7.3SuperTrak66 BIOS Error Messages
On bootup, the SuperTrak66 BIOS will initialize. Should an error be detected, the following messages will appear on screen and the bootup process halted.
Message: | No Array is defined… |
Cause: | Either no drives are detected, or the drives detected are not |
| assigned to an array. The SuperTrak66 BIOS only provides int 13h |
| support for defined arrays. If there are no drives detected, or the |
| detected drives are not assigned to an array, then the BIOS has |
| nothing to support for int 13h. You must use the SuperBuild utility |
| to define an array using drives attached to the SuperTrak66. |
Message: | Problem is detected with Array : X |
Cause: | There is a critical or offline array. A fault tolerant array will require |
| one of the drives to be replaced (if a hot spare has not already |
| been invoked). A |
| offline, and is no longer accessible. |
- 112 -